ConceptWall 60
Technical informationPerformance
Energy
- Thermal insulation - Uf
- 0.6 W/m²K
Comfort
- Air tightness
- AE 1950 (1950Pa)
- Water tightness
- RE1950 (1950Pa)
- Wind load resistance
- E2400 (2400Pa)
- Air tightness
- 1 (150 Pa)
- Water tightness
- Class E1200 (1200Pa)
- Acoustics - Rw(C;Ctr)
- 55 (-2;-7) dB
Safety
- Burglar resistance
- RC2 - RC3
- Impact resistance
- I5 - E5
Properties
Max. dimensions & weight
- Max. weight of glass
- 750 kg
- Min. intertia mullion - Ix
- 45 cm4
- Max. intertia mullion - Ix
- 1940 cm4
- Min. intertia transom - Ix
- 45 cm4
- Max. intertia transom - Ix
- 871 cm4
- Min. intertia transom - Iy (glass load)
- 33 cm4
- Max. intertia transom - Iy (glass load)
- 111 cm4
Sightlines
- Min. width T-profile
- 60 mm
- Min. visible width (interior view)
- 60 mm
- Min. visible width (exterior view)
- 60 mm
- Min. depth mullion
- 62.5 mm
- Max. depth mullion
- 251.5 mm
- Min. depth transom
- 67.2 mm
- Max. depth transom
- 214.3 mm
Glazing
- Glazing method
- Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 60 mm